  • 2233A4B - 22 7/30 BC 1015 | Sequel Wire

    2233A4B - 22 7/30 BC 1015 Description 22 1015 Product # 2233A4B Gauge 22 AWG Stranding 7/0096 BC LHL Insulation PVC Voltage 600V Temperature 80/105 C Style 1015 Notes Description only change on stranding. Product is still manufactured the same as it as always been. Print Legend E516147 22 AWG (0.324mm2) (UL) MTW or AWM 1011/1015/1230/1335 105C 600V or 1032 1000V MOISTURE RESISTANT VW-1 -- 301259 CSA TEW 105C 600V FT1 or AWM I A/B 105C 600V FT1 Diameter 0.091 Tolerance +/- 0.003 Nom Wall 0.03 Min Wall 0.027 Tolerances unless otherwise noted: FRACTIONS +/- 1/32, DECIMALS +/- 0.03 (2PL) +/-0.005 (3PL) View Spec Sheet PDF Previous Item Next Item

  • 1233A4B - 12 65/30 BC 1015 | Sequel Wire

    1233A4B - 12 65/30 BC 1015 Description 12 Boat/MTW/1015 Product # 1233A4B Gauge 12 AWG Stranding 65/30 BC LHL Insulation PVC Voltage 600V, 1000V Temperature 105 C Style Boat, MTW, 1011, 1015, 1230, 1335, 1032, TEW Notes 1. Insulating material tested to rate -40C Print Legend E517536 12 AWG (3.31mm2) (UL) BC-5W2 or MTW or THHW or AWM 1011/1015/1230/1335 105C 600V or 1032 1000V MOISTURE RESISTANT VW-1 -- 301259 CSA TEW or AWM I A/B 105C 600V FT1 Diameter 0.148 Tolerance +/- 0.003 Nom Wall 0.03 Min Wall 0.027 Tolerances unless otherwise noted: FRACTIONS +/- 1/32, DECIMALS +/- 0.03 (2PL) +/-0.005 (3PL) View Spec Sheet PDF Previous Item Next Item

  • The Appliance & HVAC Report Issue Featuring Sequel | Sequel Wire

    The Appliance & HVAC Report Issue Featuring Sequel March 24, 2022 Sequel adds Todd Eagan as Sales Manager in December 2021: After launching in 2020 and succeeding despite global economic challenges, Sequel is continuing to deliver on their dedication to exceeding customer expectations by hiring a new sales manager, additional employees, and expanding facility capabilities. Todd Eagan was sought out by Sequel and selected as Sales Manager due to his depth of knowledge and experience of more than 30 years in nearly every aspect of the wire and cable supply chain and major components. His diverse background covers the process from start to finish, including cast copper rod, compounds, and commercial uninsulated and insulated wire. He understands the interrelation of purchasing, manufacturing and selling the raw materials necessary to make insulated wire. First Prev 1 Page 1 Next Last

  • 1843A4T - 18 16/30 TC 3173 | Sequel Wire

    1843A4T - 18 16/30 TC 3173 Description 18 AWM 3173/3237 Product # 1843A4T Gauge 18 AWG Stranding 16/30 TC Insulation XLPE Voltage 600V, 1000V Temperature 125C Style AWM, 3173, 3237 Notes Print Legend Diameter 0.104 Tolerance +/- 0.003 Nom Wall 0.03 Min Wall 0.027 Tolerances unless otherwise noted: FRACTIONS +/- 1/32, DECIMALS +/- 0.03 (2PL) +/-0.005 (3PL) View Spec Sheet PDF Previous Item Next Item

  • 2243A4T - 22 7/30 TC 3173 | Sequel Wire

    2243A4T - 22 7/30 TC 3173 Description 22 AWM 3173 Product # 2243A4T Gauge 22 AWG Stranding 7/0096 TC Insulation XLPE Voltage 600V, 1000V Temperature 125C Style AWM, 3173, 3237 Notes Print Legend Diameter 0.091 Tolerance +/- 0.003 Nom Wall 0.03 Min Wall 0.027 Tolerances unless otherwise noted: FRACTIONS +/- 1/32, DECIMALS +/- 0.03 (2PL) +/-0.005 (3PL) View Spec Sheet PDF Previous Item Next Item

  • Wire Journal News - Sequel Expansion Update | Sequel Wire

    Wire Journal News - Sequel Expansion Update April 3, 2022 Wire Journal News features update on Sequel expansion: Sequel Wire Completes Expansion Featured Sequel Wire and Cable reports that, since launching the business in Argos, Indiana, in January 2020, it has been successful despite global economic challenges. Those results led to a need for more capacity, and the insulated copper wire manufacturer recently completed an expansion and has hired a new sales manager. A press release said that in July 2021, after six months of insulating products, Sequel needed to expand production to meet demand. A year later, the Phase 1 production expansion to the 162,000-sq-ft greenfield site has been completed, and is fully operational. The facility expansion has doubled internal wire drawing capabilities, and raised PVC wire output by a third. The company said that the investments have made for more flexibility and shorter lead times for customers. It has also provided enhanced control since the need to source uninsulated wire externally was significantly reduced. First Prev 1 Page 1 Next Last

  • 0615B9B - 6 133/.0137 BC SGT 105C | Sequel Wire

    0615B9B - 6 133/.0137 BC SGT 105C Description 6 133/ BC SGT 105C Product # 0615B9B Gauge 6 AWG Stranding 133/0139 BC Insulation PVC Voltage 60V Temperature 105C Style SGT per SAE J-1127, 202012 Notes N/A Print Legend SEQUEL 6 AWG SAE J1127 SGT2 105C Diameter 0.301 Tolerance +/- 0.01 Nom Wall 0.06 Min Wall 0.042 Tolerances unless otherwise noted: FRACTIONS +/- 1/32, DECIMALS +/- 0.03 (2PL) +/-0.005 (3PL) View Spec Sheet PDF Previous Item Next Item

  • WNIT Marshall County Economic Outlook | Sequel Wire

    WNIT Marshall County Economic Outlook October 15, 2019 Jerry Chavez, President of Marshall County Economic Development, discusses the economic outlook for Marshall County, including the jobs created by Sequel. First Prev 1 Page 1 Next Last

  • 1623B3B - 16 19/29 BC UL/SAE GXL3 | Sequel Wire

    1623B3B - 16 19/29 BC UL/SAE GXL3 Description 16 UL/GXL Product # 1623B3B Gauge 16 AWG Stranding 19/29 BC Insulation XLPE Voltage 60V Temperature 125C Type 3 Style SAE, J-1128, 202012 Notes Print Legend Diameter 0.102 Tolerance +/- 0.003 Nom Wall 0.023 Min Wall 0.016 Tolerances unless otherwise noted: FRACTIONS +/- 1/32, DECIMALS +/- 0.03 (2PL) +/-0.005 (3PL) View Spec Sheet PDF Previous Item Next Item

  • 1213B3T - 12 19/25 TC GPT MARINE | Sequel Wire

    1213B3T - 12 19/25 TC GPT MARINE Description 12 GPT2 Marine Product # 1213B3T Gauge 12 AWG Stranding 19/25 TC LHL Insulation PVC Voltage 60V Temperature 105C Style GPT2 per SAE, J-1128, 202012 Notes N/A Print Legend SEQUEL 12 AWG Marine SAE J378 and SAE J1128 105C 60V DC Diameter 0.145 Tolerance +/- 0.003 Nom Wall 0.026 Min Wall 0.018 Tolerances unless otherwise noted: FRACTIONS +/- 1/32, DECIMALS +/- 0.03 (2PL) +/-0.005 (3PL) View Spec Sheet PDF Previous Item Next Item

  • 0435A3B - 4 19/.0469 BC 1283 | Sequel Wire

    0435A3B - 4 19/.0469 BC 1283 Description 4 19/ BC 1283 Product # 0435A3B Gauge 4 AWG Stranding 19/0469 BC Insulation PVC Voltage 1000V, 600V Temperature 105C Style MTW/AWM, 1283 Notes Print Legend Diameter 0.36 Tolerance +/- 0.005 Nom Wall 0.06 Min Wall 0.054 Tolerances unless otherwise noted: FRACTIONS +/- 1/32, DECIMALS +/- 0.03 (2PL) +/-0.005 (3PL) View Spec Sheet PDF Previous Item Next Item

  • 1833A4T - 18 16/30 TC 1015 | Sequel Wire

    1833A4T - 18 16/30 TC 1015 Description 18 MTW/1015 Product # 1833A4T Gauge 18 AWG Stranding 16/30 TC LHL Insulation PVC Voltage 600V, 1000V Temperature 105 C Style MTW, 1011, 1015, 1230, 1335, 1032, TEW Notes 1. Insulating material tested to rate -40C Print Legend E516147 18 AWG (0.823mm2) (UL) MTW or AWM 1011/1015/1230/1335 105C 600V or 1032 1000V MOISTURE RESISTANT VW-1 -- 301259 CSA TEW 105C 600V FT1 or AWM I A/B 105C 600V FT1 Diameter 0.104 Tolerance +/- 0.003 Nom Wall 0.03 Min Wall 0.027 Tolerances unless otherwise noted: FRACTIONS +/- 1/32, DECIMALS +/- 0.03 (2PL) +/-0.005 (3PL) View Spec Sheet PDF Previous Item Next Item