  • 1033A4T - 10 105/30 TC 1015 | Sequel Wire

    1033A4T - 10 105/30 TC 1015 Description 10 Boat/MTW/1015 Product # 1033A4T Gauge 10 AWG Stranding 105/30 TC Insulation PVC Voltage 600V, 1000V Temperature 105C Style Boat, MTW, 1011, 1015, 1230, 1335, 1032, TEW Notes 1. Insulating material tested to rate -40C Print Legend E517536 10 AWG (5.261mm2) (UL) BC5W2 or MTW or THHW or AWM 1011/1015/1230/1335 105C 600V or 1032 1000V MOISTURE RESISTANT VW-1 -- 301259 CSA TEW or AWM I A/B 105C 600V FT1 Diameter 0.173 Tolerance +/- 0.003 Nom Wall 0.03 Min Wall 0.027 Tolerances unless otherwise noted: FRACTIONS +/- 1/32, DECIMALS +/- 0.03 (2PL) +/-0.005 (3PL) View Spec Sheet PDF Previous Item Next Item

  • 0235A4B - 2 665/.0099 BC 1283 | Sequel Wire

    0235A4B - 2 665/.0099 BC 1283 Description 2 7X95/ BC 1283 Product # 0235A4B Gauge 2 AWG Stranding 665/0099 BC Insulation PVC Voltage 1000V, 600V Temperature 105C Style MTW/AWM, 1283 Notes Print Legend Diameter 0.435 Tolerance +/- 0.004 Nom Wall 0.06 Min Wall 0.054 Tolerances unless otherwise noted: FRACTIONS +/- 1/32, DECIMALS +/- 0.03 (2PL) +/-0.005 (3PL) View Spec Sheet PDF Previous Item Next Item

  • FP164A1B | Sequel Wire

    16/4C SOL BC FIRE PLN UNS Download PDF Description Fire Alarm Unshielded Cable Plenum Product # FP164A1B Industry FIRE ALARM Gauge 16 AWG Conductors 4C Stranding Solid Shielding Unshielded Cond. Type BC Nom. Dia. 0.182 Previous Item Next Item

  • Sequel Wire and Cable | copper wire and cable | OEM and low voltage

    Manufacturer and supplier of OEM and low-voltage wire and cable: UL/CSA, SAE, CMR, CMP, FPLR, FPLP, lead wire, hookup wire, machine tool, marine, building, agricultural, appliance, automotive, battery, construction, control panel, EV charging, heavy duty truck, home wiring panel prep, marine, boat, motorcycle, off-road Vehicle, RV, trailer, water heaters, welding cable, security intrusion, access control, thermostat, fire alarm, access control, AV sound systems, landscape lighting, PV cable Quality, Customer-DriveN, AGILE SEQUEL WIRE & CABLE Play Video OEM MARKETS UL/CSA as well as SAE wire Agricultural Equipment Appliance Automotive Battery Battery Electric Power and Charging Construction Equipment Control Panel Electric Vehicle Charging Heavy-Duty Truck Home Wiring Panel Prep Marine Motorcycle Off-Road Vehicle RV and Trailer Water Heaters Welding Cable/ Commercial Welders PV Cable LOW VOLTAGE MARKETS CMR, CMP, FPLR, FPLP Security/Intrusion Access Control Thermostat Fire Alarm Access Control Audio Visual and Sound Systems Landscape Lighting Audio Visual and Sound Systems Automotive Landscape Lighting Home Wiring Panel Prep Fire Alarm Systems Welding Thermostat Appliances Marine Access Control Alternative Energy Battery Electric Power and Charging PRODUCT Markets Drawing and extrusion of insulated copper wire for use in a variety of markets Product categories Product categories Product categories Product categories OEM Products Shop All Low Voltage Shop All Latest Updates Stay informed with our latest news and product releases. Explore the innovations and advancements in the wire and cable industry. Read More Product Focus We are always expanding our capabilities and product offerings to meet our customers changing needs Market Trends As market conditions change we will keep you informed about the effects on pricing and availability Company News Our employees and leadership are some of the industry best. Meet new people on our teams Stay Connected Sign up for our newsletter to be the first to hear announcements and plans for what is next at Sequel Great Place to Work® Certified™ 2022-27 ISO 9001:2015 Made in USA Certifications & Awards We pride ourselves on our qualifications and certifications, ensuring that our team is equipped with the necessary expertise to deliver exceptional service. First* Last* Email* Phone Company Role* Message We collect your phone number and email address through our contact information form, and with your consent we will send you text messages or emails on a regular basis if you’ve opted in. Reply STOP at any time to unsubscribe from text messages or emails.* Submit CONTACT US ASK QUESTIONS AND GET updateS New releases, news, and upcoming events

  • 1413A3B - 14 19/27 BC GPT 105C | Sequel Wire

    1413A3B - 14 19/27 BC GPT 105C Description 14 GPT2 105C Product # 1413A3B Gauge 14 AWG Stranding 19/27 BC LHL Insulation PVC Voltage 60V Temperature 105C TYPE 2 Style GPT2 per SAE, J-1128, 202012 Notes N/A Print Legend N/A Diameter 0.119 Tolerance +/- 0.003 Nom Wall 0.023 Min Wall 0.016 Tolerances unless otherwise noted: FRACTIONS +/- 1/32, DECIMALS +/- 0.03 (2PL) +/-0.005 (3PL) View Spec Sheet PDF Previous Item Next Item

  • TP186A1B | Sequel Wire

    18/6C SOL BC HVAC PLN UNS Download PDF Description Thermostat Cable Plenum Product # TP186A1B Industry HVAC Gauge 18 AWG Conductors 6C Stranding Solid Shielding Unshielded Cond. Type BC Nom. Dia. 0.182 Previous Item Next Item

  • 1043A4T - 10 105/30 TC 3173 SIS | Sequel Wire

    1043A4T - 10 105/30 TC 3173 SIS Description 10 TC SIS/AWM 3173/3237 Product # 1043A4T Gauge 10 AWG Stranding 105/30 TC Insulation XLPE Voltage 600V, 1000V Temperature 125C Style SIS, AWM, 3173, 3237 Notes 1. Insulating material tested to rate -40C Print Legend E520012 10 AWG (5.261mm2) UL SIS 600V or 3173 125C 600V or 3237 1000V -- 301259 CSA CL1251 125C 600V or AWM I A/B 125C 600V FT2 Diameter 0.173 Tolerance +/- 0.003 Nom Wall 0.03 Min Wall 0.027 Tolerances unless otherwise noted: FRACTIONS +/- 1/32, DECIMALS +/- 0.03 (2PL) +/-0.005 (3PL) View Spec Sheet PDF Previous Item Next Item

  • 1423A3B - 14 19/27 BC GXL3 | Sequel Wire

    1423A3B - 14 19/27 BC GXL3 Description 14 GXL Product # 1423A3B Gauge 14 AWG Stranding 19/27 BC Insulation XLPE Voltage 60V Temperature 125C Type 3 Style SAE, J-1128, 202012 Notes N/A Print Legend N/A Diameter 0.119 Tolerance +/- 0.003 Nom Wall 0.023 Min Wall 0.016 Tolerances unless otherwise noted: FRACTIONS +/- 1/32, DECIMALS +/- 0.03 (2PL) +/-0.005 (3PL) View Spec Sheet PDF Previous Item Next Item

  • 1423B3B - 14 19/27 BC UL/SAE GXL3 | Sequel Wire

    1423B3B - 14 19/27 BC UL/SAE GXL3 Description 14 UL/GXL Product # 1423B3B Gauge 14 AWG Stranding 19/27 BC Insulation XLPE Voltage 60V Temperature 125C Type 3 Style SAE, J-1128, 202012 Notes N/A Print Legend E515416 14 AWG (UL) SAE GXL3 125C Diameter 0.119 Tolerance +/- 0.003 Nom Wall 0.023 Min Wall 0.016 Tolerances unless otherwise noted: FRACTIONS +/- 1/32, DECIMALS +/- 0.03 (2PL) +/-0.005 (3PL) View Spec Sheet PDF Previous Item Next Item

  • Products OEM PV (List) | Sequel Wire

    OEM CABLE OEM CABLE OEM CABLE OEM CABLE OEM PRODUCT LINE: Certified to Produce HOOKUP WIRE Appliance Wiring Material: Single Conductor, Thermoplastic Insulation: 1007, 1011, 1015, 1028, 1032, 1061, 1230, 1231, 1283, 1335, 1337, 1344, 1346, 1569, 1581, 10002 Multi-Conductor, Thermoplastic Insulation: 2474 Single Conductor, Thermoset Insulation: 3173, 3195, 3199, 3237 Recreational Vehicle (RV) 2-Cond., UL SAE TWP1/2, UL SAE GPT1/2, UL SAE TXL3, UL SAE GXL3, UL SAE SXL3 Machine Tool Wire Marine Boat Cable (BC5W2 Standard 1426) Building XHHW-2 SIS (VW-1) Automotive Self-Certified Wire and Cable Products—Not Agency Rated Battery SGT 1/2, Battery STX 3/4, Battery SGX 3/4, TWP 1/2, GPT 1/2, TXL3, GXL3, SXL3, SAE MARINE (GPTM), Brake Cable (Type GPT) Product Line Pdf 8 7/0486BC PV 2KV RHW-2 08P6A2B Styles: PV, RHW-2 Industries: PV Gauges: 8 AWG Product Specs 10 7/0385 BC PV 2KV RHW-2 10P6A2B Styles: PV, RHW-2 Industries: PV Gauges: 10 AWG Product Specs 10 19/0234 BC PV 2KV RHW-2 10Р6A3B Styles: PV, RHW-2 Industries: PV Gauges: 10 AWG Product Specs Filter By MARKETS PV GAUGE AWG 8 10 STRANDING 12 10 6 4 2 STYLES PV RHW-2 Product List – PV Cable

  • 1013B3T - 10 19/23 TC GPT MARINE | Sequel Wire

    1013B3T - 10 19/23 TC GPT MARINE Description 10 19/ TC GPT2 Marine Product # 1013B3T Gauge 10 AWG Stranding 19/0223 TC LHL Insulation PVC Voltage 60V Temperature 105C Style GPT2 per SAE, J-1128, 202012 Notes N/A Print Legend SEQUEL 10 AWG Marine SAE J378 and SAE J1128 105C 60V DC Diameter 0.173 Tolerance +/- 0.003 Nom Wall 0.031 Min Wall 0.022 Tolerances unless otherwise noted: FRACTIONS +/- 1/32, DECIMALS +/- 0.03 (2PL) +/-0.005 (3PL) View Spec Sheet PDF Previous Item Next Item

  • 1833A4T - 18 16/30 TC 1015 | Sequel Wire

    1833A4T - 18 16/30 TC 1015 Description 18 MTW/1015 Product # 1833A4T Gauge 18 AWG Stranding 16/30 TC LHL Insulation PVC Voltage 600V, 1000V Temperature 105 C Style MTW, 1011, 1015, 1230, 1335, 1032, TEW Notes 1. Insulating material tested to rate -40C Print Legend E516147 18 AWG (0.823mm2) (UL) MTW or AWM 1011/1015/1230/1335 105C 600V or 1032 1000V MOISTURE RESISTANT VW-1 -- 301259 CSA TEW 105C 600V FT1 or AWM I A/B 105C 600V FT1 Diameter 0.104 Tolerance +/- 0.003 Nom Wall 0.03 Min Wall 0.027 Tolerances unless otherwise noted: FRACTIONS +/- 1/32, DECIMALS +/- 0.03 (2PL) +/-0.005 (3PL) View Spec Sheet PDF Previous Item Next Item